What this source can tell you
Read “Re-board All White 2023 EPD” as a epd record for Re-board All White; 16 mm; 1m², version 1.1. Product-specific published lifecycle indicators for the stated board variant and declared unit. Keep biogenic carbon, end-of-life scenarios and module D separate.
- Exact subject
- Re-board All White; 16 mm; 1m²
- Method / standard
- EN 15804:2012+A 2:2019/AC:2021; ISO 14025:2006
- Version
- 1.1
- Published
- 2023-09-01
- Status
- Registry valid; PDF reviewed; comparison discrepancy recorded
- Registration / report
- EPD-IES-0009596:002
- Validity
- 2028-09-01
Apply the dataset
Scale only from the declared one-square-metre board unit after checking product identity. The board EPD does not describe a complete printed fixture. Do not add module D to an A 1-A 3 result or compare total GWP with a fossil-only indicator.
Reported environmental indicators
- Declared unit
- 1 m² of 16 mm paperboard
- Indicator / module
- GWP-total · A1-A3
- Source value
- -1.56 kg CO2e per declared unit
- Boundary
- A 1-A 3 plus C1-C4; module D reported separately; A 4, A 5, B modules not declared
- Version
- PDF1.1, 2024-03-15
- Data / reporting year
- 2022
- Geography
- A1: Europe; A2: Europe; A3: Sweden; C1-C4: Global; D: Global
- Validity
- 2028-09-01
- Source location
- Page 7
- Comparison status
- Manual review required: registry PCR 1.3.4 versus PDF PCR 1.2.5
| Indicator | A1-A3 | C1 | C2 | C3 | C4 | D |
|---|---|---|---|---|---|---|
| GWP-fossil | 2.08 | 0 | 0.0175 | 0.188 | 0.00151 | -1.19 |
| GWP-biogenic | -3.65 | 0 | 0.000126 | 6.81 | 0.0000113 | -5.28 |
| GWP-luluc | 0.0159 | 0 | 0.00000851 | 0.000063 | 8.88e-7 | -0.00444 |
| GWP-total | -1.56 | 0 | 0.0177 | 6.99 | 0.00152 | -6.47 |
| GWP-GHG | 2.09 | 0 | 0.0175 | 0.188 | 0.00151 | -1.19 |
The indicators in “Re-board All White 2023 EPD” apply to Re-board All White; 16 mm; 1m². Retain that subject and its system boundary when using a value. Other graphics, finishes and event activities need applicable evidence of their own.
Limits before comparison
- End-of-life model assumes 61% recycling, 32% incineration, 7% landfill; this is not achieved local recovery.
- A negative A 1-A 3 result includes biogenic accounting and does not establish carbon neutrality.